Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (76)
- (8)
- (135)
- (9)
- (1)
- (8)
- (1)
- (3)
- (6)
- (184)
- (1)
- (3)
- (22)
- (77)
- (175)
- (51)
- (43)
- (81)
- (1)
- (1)
- (44)
- (14)
- (94)
- (18)
- (1)
- (6)
- (6)
- (26)
- (5)
- (4)
- (3)
- (4)
- (4)
- (10)
- (16)
- (7)
- (54)
- (149)
- (58)
- (2)
- (39)
- (222)
- (44)
- (17)
- (21)
- (8)
- (100)
- (30)
- (18)
- (44)
- (1)
- (32)
- (1)
- (2)
- (13)
- (4)
- (1)
- (1)
- (15)
- (1)
- (6)
- (25)
- (27)
- (1)
- (1)
- (2)
- (73)
- (5)
- (1)
- (1)
- (1)
- (35)
- (1)
- (1)
- (735)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (340)
- (288)
- (6)
- (2)
- (3)
- (130)
- (563)
- (59)
Filtered Search Results
Cytiva Whatman™ Nylon Membrane Circle
For filtering aqueous solutions and most organic solvents
Cytiva GN Metricel™ Membrane Disc Filters
Certified for the microbiological analysis of potable, waste, process, and natural waters in accordance with the Membrane Filter Technique referenced in Standard Methods for the Examination of Water and Wastewater.
Cytiva Whatman™ Sterile Mixed Cellulose Ester Gridded Membranes
Composed of cellulose acetate and cellulose nitrate.
Cytiva Whatman™ Mixed Cellulose Ester Membranes
Color contrast helps easier particle detection.
Cytiva Whatman™ Non-Sterile Cellulose Nitrate Membranes
Narrow pore size distribution for improved surface capture and analysis.
Sartorius Cellulose Acetate Membrane Filter
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cellulose acetate membrane filters with 142 mm diameter combine thermal stability with exceptionally low adsorption characteristics.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Diameter (Metric) | 142 mm |
| Quantity | 25/Cs. |
| Material | Cellulose Acetate |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
Cytiva Whatman™ Cyclopore PC Polycarbonate Membrane Filters
Microporous membranes featuring sharp cut-off and reproducible lab microfiltration characteristics of track-etched membrane filters
| Type | Membrane filters |
|---|---|
| Temperature (English) Operating | 284 °F |
| Pore Density | Min: 105 pores/cm2, Max: 6 x 108 pores/cm2 |
| Quantity | 100 Pk. |
| Material | Polycarbonate |
| Porosity | Min: 4%, Max: 20% |
| Temperature (Metric) Operating | 140 °C |
| For Use With (Application) | For general filtration, Cross-flow filtration, Air and water monitoring, Microorganism analysis, Healthcare applications, Immunodiagnostics |
| Autoclavable | Autoclavable |
Cytiva Whatman™ Regenerated Cellulose Membranes: Grade RC 60
Consists of pure cellulose without any wetting agents
| Thickness (Metric) | 70 μm |
|---|---|
| Pore Size | 1.0 μm |
| Material | Regenerated Cellulose |
| Hydrophobicity | Hydrophilic |
MilliporeSigma™ Isopore™ Membrane Filters, 0.6 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.
| Pore Size | 0.6 μm |
|---|---|
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
| Sterility | Non-sterile |
| Bubble Point | 8.5 psi |
| Flow Rate | Avg. 43 mL/min x cm2 (typical results (at 10 psi);62 mL/min x cm2/psi) |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
| Gas Flow Rate | 10.0 L/min/cm2 |
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.22 μm
Hydrophobic membrane with laminated backing for easier handling
| Pore Size | 0.22 μm |
|---|---|
| Flow Rate | 24 mL/min x cm2 |
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophobic |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Cytiva Whatman™ 90 mm Nuclepore™ Polycarbonate Track-Etched Membranes
Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.
| Flow Rate | High |
|---|---|
| Diameter (Metric) | 90 mm |
| Material | Nucleopore Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Epifluorescence microscopy, environmental analysis, cell biology |
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.45 μm
Hydrophobic membrane with laminated backing for easier handling
| Pore Size | 0.45 μm |
|---|---|
| Bubble Point | 7 psi |
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Diameter (Metric) | 47 mm |
| Color | White |
| Quantity | 100/Pk. |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Clarification of Acids, Bases and Solvents; Clarification of Alcohol Solutions; UV Spectroscopy. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 8.0 L/min/cm2 |
Cytiva Whatman™ ME 24 Plain Mixed Cellulose Ester Membranes
Enables the uptake of growth media to the bacterial colonies without chemically inhibiting their growth. Whatman™ ME 24 Plain Mixed Cellulose Ester Membranes are composed of cellulose acetate and cellulose nitrate, which provides a more uniform surface.
| Thickness (Metric) | 135 μm |
|---|---|
| Includes | Interleaving paper |
| Pore Size | 0.2 μm |
| Bubble Point | 3.7bar |
| Flow Rate | 20s/100mL/12.5cm2 |
| Grid Color | Plain |
| Material | MCE |
| Autoclavable | Autoclavable |
| Membrane Type | ME24 |
| Pore Size | 0.2 μm |
|---|---|
| No. per Case | 100 Pk. |
| Quantity | 100 Pk. |
| Material | Nylon |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Clarifying aqueous or organic solutions prior to HPLC analysis. |
| Sterility | Non-sterile |
| Bubble Point | 40 psi |
| Flow Rate | 15 (at 690 Mbar (10 psi)) |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Format | Disc |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
MilliporeSigma™ Fluoropore™ Membrane Filters, 5 μm
Hydrophobic membrane with laminated backing for easier handling